11-29
2019year
1400c High Temperature High Vacuum Tube Furnace With

High Temp Tube Furnace PV 1800 using high purity alumina tube as the furnace tube, working temperature range 800 ℃ to 1800 ℃, This series of equipment of international advanced control system, has safe and reliable, simple operation, high precision temperature control, heat preservation effect is good, high uniformity of furnace temperature, can connect vacuum atmosphere etc., are widely

11-29
2019year
CM Furnaces Inc

In particular our focus on high temperature continuous processing in controlled atmospheres accommodates a wide range of materials and processes. ABOUT US CM Furnaces is known for state of the art design and manufacturing of all types of air, hydrogen and inert atmosphere electric furnaces.

11-29
2019year
Inert Gas Vacuum Heat Treatment Furnace

Vacuum Heat Treatment of Tools and Dies and other components of tool steel material like HSS, Hot Work Tool Steels, Cold Work Tool Steels, Martensitic Stainless Steels etc. which are gas quenchable are offered by ALD Dynatech through their MONOTHERM Single Chamber Vacuum Heat Treatment Furnaces with temperature capability of up to 1,320 C and with inert gas quench pressures up to 12-bar (a).

11-29
2019year
Chemical manipulation of hydrogen induced high p-type and n

2 gas at 580 torr pressure. After filling the tube with hydrogen, the open end was properly sealed. The ampoule was placed in an oven where temperature can be precisely controlled. The temperature was increased in two steps up to the desired value and H 2 was allowed to diffuse into the crystal for 1 or 2 hours. A few other samples of same

11-29
2019year
Exogas Endothermic Generator - Heat treatment furnace, vacuum

Nozzle mix units require a fuel gas pressure of 3 psi (15 mm Hg). Smaller units utilizing the premix design require fuel gas pressure from .1 to 1 psi (5 to 52 mm Hg). Gas pressures higher than stated will require service regulators while gas pressures lower than stated will require the addition of a gas booster.

11-29
2019year
Lab Furnace | kejia furnace

Tube furnace, for charging nitrogen or evacuated, you can directly buy a vacuum furnace, general structure:a tube furnace quartz tube liner, two stainless steel seals, headed inlet valve, single-head outlet valves, a vacuum gauge, a flow meter. Kejia Furnace,there are high cost-effective on our lab furnace and dental furnace.

11-29
2019year
Annealing furnace, Annealing oven - All industrial

The unit can bear a maximum load capacity up to 100 t, and a maximum load length up to 13000 mm. This furnace employs a high-speed gas burner for reheating. It

11-29
2019year
Controlled Atmosphere Oven HTMA - CARBOLITE GERO

Controlled Atmosphere Oven - HTMA. Language: The HTMA series is a range of modified atmosphere high temperature ovens for use with inert atmospheres up to 700°C. Separate flow controls for purge and process gases mean that once the chamber has been purged of atmospheric air process gas can be used with lower flow rates.

11-29
2019year
Gas Supply Systems/Vacuum Operation for Tube Furnaces

Gas Supply System 4 for gas-tight operation with hydrogen, introduced at room temperature/vacuum operation Adding gas supply system 4 to the tube furnace allows operation under a hydrogen atmosphere. The built-in safety system allows the introduction of hydrogen into the working tube at room temperature.

11-29
2019year
Ultra-high temperature vacuum atmosphere furnace

Furnace temperature uniformity of ± 3 ℃, temperature measurement element thermocouple platinum and rhodium S thermocouple, temperature range 0-1700 degrees, the heating element installed position: both sides (using silicon carbide heating), the heating rate can be adjusted freely, the adjustment range : The fastest heating rate of 40 degrees per minute (40 ℃ / min), the slowest heating rate of 1 degree per hour (1 ℃ / h).

11-29
2019year
1100°C Hydrogen Gas Tube Furnace with 60mm Superalloy Tube

CY-1200X-60HG is a safe hydrogen tube furnaces The processing tube is made of high quality Ni-based superalloy which never crack and broken at flowing Hydrogen gas. One 3M hydrogen detector is included which will shut down Hydrogen gas generator and gas inlet valve immediately once detecting hydrogen gas leaking . The tube furnace is designed for processing material under hydrogen gas up to 1100°C safely. Also, the furnace can be used for all kind of inert gasses and oxygen gas up to 30 PSI.

11-29
2019year
Vacuum Hydrogen Furnace - Vacuum Furnace

High vacuum hydrogen furnace is mainly used for vacuum tempering of materials like tool steel, die steel, high-speed steel, ultra-strength steel, stainless steel after vacuum quenching and solution treatment. It is also for re-crystallization annealing and vacuum aging of non-ferrous metal under hydrogen gas condition. Technical Features 1.

11-29
2019year
Atmosphere Control System for Annealing Furnaces

ple system and gas analyzers. The flow train is equipped with pro-portional valves and flow trans-mitters. The furnace atmosphere from the hot and cooling Liisa Åström, M. Sc. (Chem. Eng.) Application Manager Vaisala Helsinki Finland Dewpoint monitoring in harsh environments Atmosphere Control System for Annealing Furnaces

11-29
2019year
Model LRS Thermal Gas Mass Flowmeter

Direct mass flow measurement without temperature and pressure compensation. High precision measurements can also be obtained at low range. Maximum range ratio to 1:1000, with leak detection function. Short response time. Pressure loss is negligible. No movable parts, using aseismic design. Easy installation and high economy.

11-29
2019year
Lab Furnaces | Thermo Fisher Scientific - US

Lab Oven & Furnace Accessories › Consistent performance at a high degree Designed with safety in mind, Thermo Scientific furnaces offer temperature ranges from 1100° to 1700°C, temperature control options to meet your application needs, as well as features that help you perform the most critical, as well as everyday applications.

11-29
2019year
Lab Equipment - HighPak

HP8-VF1200D8 is a vacuum chamber furnace with 8" diameter x 7" height vertical quartz liner and stainless steel vacuum flange. It is designed for calcining or sintering ceramic material or annealing semiconductor wafer under vacuum or various gas atmosphere up to 1200oC.

11-29
2019year
Is it safe to anneal a material in a hydrogen atmosphere

Is it safe to anneal a material in a hydrogen atmosphere given the fact that hydrogen is highly combustible? Are any special precautions necessary to do this ? (Annealing temperature 400 to 500

11-29
2019year
Heat Treatment | Linde Gas

Heat treatment involves controlling numerous parameters in order to achieve specific metallurgical properties in a given material. We offer technologies and in-depth know-how to enable precision control of some of the most critical parameters within the various heat treatment processes.

11-29
2019year
Thermal processes in semiconductor technology

Meanwhile Koyo developed also high temperature versions of the vertical furnace for temperature up to 1350°C, using special heating elements, SiC tubes and boats (see picture). Forming Gas and Hydrogen Anneal. Hydrogen can cover dangling bonds and can heal defects. These processes are operated at temperatures around 400°C.

11-29
2019year
FURNACE, High-Temperature | Data Book & Buyers Guide

Find suppliers and manufacturers of ceramics, glass, Refractories, brick and FURNACE, High-Temperature in the ceramic industry. FURNACE, High-Temperature | Data Book & Buyers Guide This website requires certain cookies to work and uses other cookies to help you have the best experience.