11-25
2019year
Tempsens 2013 Catlogue - spectronics.hu

Compensating and Extension Cables for thermocouples J, K, T,E, N, R, S, B Types. RTD Cables in three wire & four wire configuration for simplex and six & eight wire for duplex are available.

11-25
2019year
Thermocouples-Thermocouple Types- J, K, E, T, N, B, R, S

Composed of a positive leg which is approximately 70% Platinum, 30% Rhodium and a negative leg which is approximately 94% Platinum, 6% Rhodium. When protected by compacted mineral insulation and appropriate outer sheath, Type R is usable from 0 to 1482°C, ( 32 to 2700°F).Type R has a higher EMF output than type S.

11-25
2019year
High Temperature Exotic Thermocouple Probes, Tantalum

Description. OMEGA™ Exotic Thermocouple Probes are designed for use in extreme temperatures, up to 2315°C (4200°F). These probes utilize either Platinum/Rhodium (types R, S, or B) or Tungsten/Rhenium (types G, C, or D) elements, with a variety of insulations and sheath materials.

11-25
2019year
Uninsulated, Fine Gage, Platinum-Rhodium Thermocouple Wire

Type S: Platinum (-) Platinum 10% Rhodium (+) Type R: Platinum (-) Platinum 13% Rhodium (+) Type B: Platinum 6% Rhodium (-) Platinum 30% Rhodium (+) Types R and S are recommended for continuous use in oxidizing or inert atmospheres up to 1400°C or short term exposures to 1480°C. Type B is rated for continuous use up to 1700°C in oxidizing or

11-25
2019year
High Quality K/s/b/r Type Thermocouple For High Temperature

K/S/B/R type thermocouple are easy to use, Thermocouples are the most popular temperature sensors. They are cheap, interchangeable, have standard connectors and can measure a wide range of temperatures. K/S/B/R type thermocouple. Platinum Rhodium Assembling Type Thermocouple is widely used in production places with high temperature.

11-25
2019year
The difference between K type thermocouple and J type

J-type thermocouples can be used in vacuum, oxidation, reduction and inert atmosphere, but the positive iron in the high temperature oxidation faster, so the use of temperature is limited, can not be directly unprotected at high temperatures for vulcanization atmosphere K-type thermocouple As a temperature sensor, K-type thermocouple and

11-25
2019year
Type R Thermocouple - Type R Thermocouples - R Type

Type R Thermocouple (Platinum Rhodium -13% / Platinum): The Type R is used in very high temperature applications. It has a higher percentage of Rhodium than the Type S, which makes it more expensive. The Type R is very similar to the Type S in terms of performance.

11-25
2019year
Electric Furnace

Heat treatment furnace, Pit type furnace, Combustion furnace, Induction furnace, Muffle furnace etc. Electric furnaces are more cheaper than oil fired furnaces and gas fired furnace.To make an Electric furnace refractory bricks, heating elements, compensating cables, thermocouples, temperature Indicator-cum-controller etc. required.

11-25
2019year
Thermocouple - Wikipedia

Types B, R, and S thermocouples use platinum or a platinum/rhodium alloy for each conductor. These are among the most stable thermocouples, but have lower sensitivity than other types, approximately 10 µV/°C. Type B, R, and S thermocouples are usually used only for high-temperature measurements due to their high cost and low sensitivity. Type B

11-25
2019year
donar.messe.de

Distributor Thermocouples Furnace Crown Thermocouples Refiner Thermocouples Annealing Lehr Thermocouples Spout Bowl Thermocouples Glass Level Probes Fish-Hook Thermocoup es REFRACTORY THERMOCOUPLES Type Sheath material Sheath Dia Standard transition sleeve Insulation material (operating temperature upto 23000C) Platinum Rhodium, Tantalum, Rhenium,

11-25
2019year
Platinum-Rhodium Thermocouple Wire | Uninsulated

Platinum 10% Rhodium (+) Type R: Platinum (–) vs. Platinum 13% Rhodium (+) Type B: Platinum 6% Rhodium (–) vs. Platinum 30% Rhodium (+) Types R and S are recommended for continuous use in oxidizing or inert atmospheres up to 2550°F (1398°C) or short term exposures to 2700°F (1482°C).

11-25
2019year
Platinum Thermocouple R Type | Platinum Thermocouple

Platinum Thermocouple R Type/ S Type. Made from the finest platinum and platinum-rhodium alloy, these type R thermocouples and type S thermocouples cover a temperature range of 0 °C to 1450 °C with uncertainties as good as 0.15 °C over most of that range.

11-25
2019year
Zirconium Diboride composite ceramic thermocouple for furnace

It is difficult for double platinum and rhodium to measure 1750-1800℃ in long-time under oxidizing condition. The accuracy of adjusted Diboride zirconium composite ceramic thermocouple is close to double platinum and rhodium thermocouple, but its temperature repeatability and lifetime are both greater than double platinum and rhodium

11-25
2019year
Thermocouples - Silicon Carbide L Type Thermocouples

Made from the finest platinum and platinum-rhodium alloy, these type R thermocouples and type S thermocouples cover a temperature range of 0 °C to 1450 °C with uncertainties as good as 0.15 °C over most of that range.

11-25
2019year
Platinum Thermocouples - Custom Manufacturing by NSI Inc.

At Nordic Sensors Industrial Inc, we manufacture platinum thermocouples according to your needs. Feel free to use our configuration tools to build your type S, type B or type R thermocouple. You may also let our engineering department custom-design and build your platinum thermocouples the way you require.

11-25
2019year
Type S Thermocouple - Type S Thermocouples - Type S Thermocouple

Type S Thermocouple (Platinum Rhodium - 10% / Platinum): The Type S is used in very high temperature applications. It is commonly found in the BioTech and Pharmaceutical industries. It is sometimes used in lower temperature applications because of its high accuracy and stability.

11-25
2019year
Thermocouple Standards 0 to 1600°C Platinum / Platinum Rhodium

Platinum / Platinum Rhodium. g. Type R and Type S . g. Gas Tight Assembly . g. Premium Grade Wire . The Isothermal range of Thermocouple Standards are the result of many years development. The type R and S . standards will cover the range from 0°C to 1600°C. The measuring assembly comprises a 7mm x 300mm or . 600mm gas tight 99.7%

11-25
2019year
Special refractories for use at high temperature

Arsemvacuumfurnaceandthehigh-frequency^inductionfurnace have beenused to fire cruciblesto temperatures in therange1,700° to 2,000°C.Inthe latter type offurnace, ahollowcylinder of

11-25
2019year
Platinum-Rhodium Thermocouple Wire | Uninsulated

Platinum 10% Rhodium (+) Type R: Platinum (–) vs. Platinum 13% Rhodium (+) Type B: Platinum 6% Rhodium (–) vs. Platinum 30% Rhodium (+) Types R and S are recommended for continuous use in oxidizing or inert atmospheres up to 2550°F (1398°C) or short term exposures to 2700°F (1482°C).

11-25
2019year
Thermocouple Manufacturers & Suppliers, China Thermocouple

Thermocouple manufacturer/supplier, China Thermocouple manufacturer & factory list, find qualified Chinese Thermocouple manufacturers, suppliers, factories, exporters & wholesalers quickly on Made-in-China.com.